top of page
Radiation Alert Monitor 200

Radiation Alert Monitor 200

The Monitor 200, your go-to solution for precise and versatile radiation detection. This state-of -the-art device measures alpha, beta, gamma, and x-rays providing accurate readings displayed in your preferred unit of measurement. Choose from CPM, CPS, μSv/hr, mR/hr, or in accumulated counts.

 

Featuring a digital backlit display, the Monitor 200 ensures easy readability in any environment. The addition of a red count light and an audible beeper accompanying each count detected enhances your awareness during radiation monitoring. With an adjustable timer and customizable loud alert, this radiation detector is tailored to meet you specific needs, offering both accuracy and user-friendly functionality.

 

Specifications

 

Detector

  • Halogen-quenched GM tube with thin mica end window. Mica window density 1.5-2.0 mg/cm2. Effective window diameter is .360 inch. Side wall is .012 inch thick.

 

Operating Range

  • mR/hr – .001 (1µR) to 200 mR/hr
  • µSv/hr – .01 to 2000
  • CPM – 0 to 235,400
  • CPS – 0 to 3923

Total Counts – 1 to 9,999,000 counts

 

 

Energy Sensitivity

  • 1070 CPM/mR/hr referenced to Cs137
  • Detects alpha down to 2.5 MeV; typical detection efficiency at 3.6 MeV is greater than 80%.
  • Detects beta at 50 keV with typical 35% detection efficiency.
  • Detects beta at 150 keV with typical 75% detection efficiency.
  • Detects gamma and x-rays down to 10 keV typical through the window, 40 keV minimum through the case.

(Ref to Cs137)

 

Accuracy of Radiation Detector Device

  • Referenced to Cs137
  • Typically ±15% from factory, ±10% with NIST Source Calibration NIST Calibration Additional

 

Anti-Saturation

  • Readout will OVERRANGE in radiation fields as high as 100 times the maximum reading.

 

 

Selectable Alert Set Range

  • mR/hr .001 – 100 and CPM 1 – 350,000. Pulsating beeper sounds the alert. Adjustable alert levels are used for mR/hr / CPM, and µSv/hr / CPS. 70db @ 1m. Alarm will sound when in Timer Mode when set alarm threshold is reached.

 

Display

  • Graphic LCD with Backlight.

 

Outputs

  • USB for use with Free Observer USB Software for PCs
  • Bluetooth Option Additoinal: Wirelessly connects the instrument with an Android mobile device for use with Free Observer BLE App

 

Count Light

  • Red LED flashes with each count.

 

Audio Indicator

  • Sounds with each count (can be switched off for silent operation)

 

Power Requirements

  • USB Power or Two (2) AA alkaline batteries (included). Approx. 800 hrs @ background.

 

Temperature Range

  • -10° to +50°C (14° to 122°F)

 

Humidity

  • 10% to 70% Non-Condensing.

 

Size

  • 140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)

 

Weight

  • 181 g (0.4 lbs.)

 

Includes

  • Carrying Case, Xtreme Boot, Lanyard, Stand, Batteries, Mini-USB Cable, Observer USB Software Download, Observer BLE App Certificate of Conformance
    logo.png
    Untitled-removebg-preview_edited.png

    Discover

    Address

    HQ Malaysia KL Address 

    10-1, Jalan SP 2/8, Taman Serdang Perdana, Seksyen2, 43300 Seri Kembangan, Selangor

    ​​

    Penang Address

    The CEO, 31-11-10, Lebuh Nipah 5, 11950 Bayan Lepas, Penang Malaysia

    Singapore Address 

    71 Bukit Batok Crescent, #10-03 Singapore, 658071​

    Contact

    HQ Malaysia Tel 

    Tel +603-8945-0998

    Fax +603-8945-3193

    Singapore Tel

    +65966852180​

    Email infor@alexcorporation.com

    Operating Hours

    Monday-Friday

    8:30 am – 6:00 pm

    Saturday & Sunday

    Closed

    bottom of page